For Georgia engineers, electrical contractors, facility teams, and procurement managers, shop drawing approval is the handoff that turns project requirements into a buildable switchgear package. A clear review process establishes who verifies technical details, how comments are resolved, and which controlled revision may proceed to fabrication—without confusing review status with design responsibility.

Made in USAUL 891 switchboard assemblies — low voltage onlyAccelerated lead times — confirm availability
Project-specific

Define the application and requirements.

Built in the USA

Discuss equipment and assembly options.

Schedule-aware

Confirm lead times for your order.

Define review roles before drawings arrive

The project team should identify the responsible electrical engineer, contractor, owner or facility representative, and purchasing contact before submittal review begins. Each has a different task: engineering checks design intent and interfaces, the contractor checks installation coordination, the owner confirms operational needs, and procurement verifies that the approved scope matches the order. One person should consolidate comments so conflicting directions are resolved rather than sent separately.

The manufacturer prepares drawings from the order documents and agreed project information; its review does not replace the engineer’s design review or the contractor’s field coordination. Confirm who has authority to mark a drawing approved, who can accept deviations, and who will issue final release. If an architect, utility, commissioning provider, or other party must review specific interfaces, assign that review explicitly and account for it in the project schedule.

Check the information that drives the build

Review the one-line diagram, equipment schedule, specifications, and purchase scope against the proposed lineup. Confirm system voltage, phases and wires, bus arrangement, main and feeder device requirements, enclosure and access expectations, metering and control functions, and any specified options. Verify that device names, circuit descriptions, and quantities match the latest project documents. These checks help expose omissions before they become fabrication changes.

Also examine project-specific conditions that affect layout and connections: incoming cable or bus entry, outgoing routing, conduit zones, available room dimensions, working clearances, equipment access path, and alignment with adjacent gear. Confirm the intended connection points and any required provisions for future circuits. Do not assume a drawing resolves field conditions that were not provided. Where dimensions or interfaces remain uncertain, assign an owner to verify them and document the result before release.

Write comments that can be resolved

Useful review comments identify the drawing sheet, location, requested change, and source requirement. Instead of writing “revise to spec,” cite the applicable project document and state the required outcome, such as correcting a feeder designation or showing a confirmed entry direction. Separate mandatory corrections from questions and preferences. This makes it easier for the manufacturer and project team to answer each item without interpreting a broad or ambiguous mark.

The reviewer should distinguish a design change from a clarification. A change to protection, control, dimensions, arrangement, or scope may affect engineering, price, schedule, or interfaces, so it needs documented authorization through the project’s change process. If a proposed arrangement is unacceptable, explain the constraint and provide the governing requirement or verified field information. The manufacturer can identify drawing impacts and confirm order implications, but the designated project authority must resolve design decisions.

Control revisions and dispositions

Maintain a revision log with the drawing number, revision identifier, issue date, review status, reviewer, and disposition of each comment. Typical dispositions include approved, approved as noted, revise and resubmit, or not approved, but use the project’s defined terms. Keep superseded sheets visibly separate from the current review set. Email attachments and marked-up prints should not become uncontrolled instructions when a later drawing has been issued.

For every comment, record whether it was incorporated, answered without a drawing change, or remains open, and identify the response sheet or note. Check that revised sheets carry consistent revision information and that changes do not create new conflicts elsewhere in the package. If review comments disagree, pause disposition and obtain a single authorized direction. Procurement should compare the resulting scope with the purchase order and route any commercial or schedule effect for approval before the manufacturer acts on it.

Authorize release for fabrication

Approval for fabrication should be an explicit, traceable instruction tied to a specific drawing revision, not an assumption based on elapsed review time or a general email saying the package looks acceptable. The release record should identify the approved set and capture any accepted notes, open items, or owner-supplied information that remains due. Do not release with unresolved decisions that could change equipment configuration, interfaces, or purchased components.

Before issuing release, confirm that required engineering and project approvals are complete, comments are closed or formally accepted, and procurement has reconciled the approved configuration with the order. The manufacturer can then confirm the applicable scope, availability, and schedule for that revision; timing is established for the specific order rather than inferred from approval alone. Changes after release require controlled review because they may affect drawings, cost, or completion timing.

Plan the Georgia project handoff

For delivery to a Georgia site, align the approved lineup and shipping arrangement with the project’s receiving plan. Confirm the ship-to location, delivery access, unloading responsibility, receiving hours, storage conditions, and whether equipment must arrive in sections or meet a staged construction sequence. These are project coordination details, not assumptions based on the destination. Provide verified constraints early so the manufacturer can review how they affect configuration, packaging, and the order schedule.

For a quote, share the current one-line diagram, specifications, equipment schedule, required options, site and interface constraints, preferred review milestones, and planned delivery location. Identify the people authorized to resolve technical comments and release the final revision. This gives procurement and engineering a practical basis to coordinate the submittal cycle and delivery. Before fabrication begins, issue one written release naming the approved revision and confirming that project comments and scope changes have been dispositioned.

Planning reference

Project specifications

Specifications are confirmed for each order
ScopeRequested by quote
VoltageBased on project requirements
CurrentSpecified to order
ListingDependent on the applicable assembly. UL 891 applies to applicable low-voltage switchboard assemblies, not medium- or high-voltage equipment.