New electrical distribution equipment, built around your projectServing Georgia
Gray electrical switchgear with meters and breaker controls inside an open enclosure.

Applications

Stadium and Arena Switchgear

Stadium and arena electrical projects must serve changing event loads while fitting construction and maintenance around a fixed calendar. We build new switchgear and UL 891 switchboard assemblies to the project’s specified configuration, with American-made components, nationwide shipping, and delivery planning for Georgia sites. Start with load requirements, operating sequences, and the dates crews can work.

Made in USAUL 891 switchboard assemblies — low voltage onlyAccelerated lead times — confirm availability
Project-specific

Define the application and requirements.

Built in the USA

Discuss equipment and assembly options.

Schedule-aware

Confirm lead times for your order.

Map the event load profile

A venue’s demand can change sharply between a dark day, a concert setup, a sold-out game, and post-event cleanup. Identify the service and distribution points in scope, expected operating modes, and major loads such as field or court systems, broadcast equipment, scoreboards, elevators, HVAC, kitchens, and life-safety systems. Provide available one-line diagrams and load schedules so the equipment configuration can be developed against the actual project design.

Ask the electrical engineer to distinguish continuous loads, intermittent loads, and loads that may operate simultaneously. Include planned renovations or future capacity needs, but separate confirmed requirements from allowances. The switchgear manufacturer needs the specified system voltage, phases, frequency, fault-current information, service arrangement, and required ratings to prepare a suitable proposal; these values must come from the project’s engineering documents, not assumptions about a typical arena.

Coordinate lighting and event production

Sports lighting, architectural lighting, video displays, and concert production can create different operating patterns and switching needs. Clarify which loads require dedicated distribution, how event and house-lighting modes are controlled, and whether temporary production power interfaces with permanent equipment. Identify dimming or control systems and their boundaries; switchgear and switchboard scope should be coordinated with the lighting designer and control-system providers.

Production changes can also affect access and shutdown planning. Confirm locations for incoming services, feeder exits, working space, cable routing, and any planned temporary connections with the electrical contractor and venue team. Share equipment-room constraints, door and pathway dimensions, and staging restrictions before configuration is finalized. These details help expose coordination issues before fabrication and reduce the chance that delivery or installation conflicts with event operations.

Account for concessions and support systems

Concession kitchens, refrigeration, beverage systems, retail areas, and loading operations may run on schedules that differ from the main event. Give the design team equipment loads, starting characteristics where relevant, and the intended grouping of circuits. A venue may need different distribution priorities for public areas, kitchens, back-of-house spaces, and event support, but the required arrangement depends on its engineered system and operating plan.

Discuss which loads must remain available during a utility interruption and which can be shed or restored in stages. Include control-room requirements, monitoring interfaces, metering needs, and any specified communications protocol in the procurement documents. Confirm which devices and controls belong in the switchgear package and which are furnished or programmed by others. Clear boundaries help the purchasing team compare proposals and avoid gaps between electrical equipment, controls, and field installation.

Define backup-power interfaces

Where standby generation or another backup source is part of the project, document the one-line arrangement and the intended transfer and restoration sequence. Identify the loads assigned to emergency, legally required standby, optional standby, or other project-defined systems as applicable. The engineer of record must establish system requirements and protective-device coordination; do not infer that a particular switchgear configuration or UL 891 designation establishes suitability for every backup-power application.

Provide generator and transfer-equipment data, source ratings, interconnection details, and any required controls or interlocks during quoting. State whether the requested scope includes switchboards, switchgear, transfer equipment, or only specified assemblies, and identify equipment supplied by other parties. Final configuration, ratings, and availability are confirmed for the order against approved project documents and applicable review by the engineer and authorities having jurisdiction.

Plan around the event calendar

Installation windows may be limited by games, concerts, graduations, seasonal schedules, and venue blackout dates. Build procurement milestones backward from the approved outage and access windows, allowing time for submittal review, coordination, site readiness, installation, testing, and commissioning by qualified personnel. Share dates that cannot move, likely shutdown duration, delivery restrictions, and any phased construction plan when requesting a quote.

For a Georgia project, nationwide shipping can support delivery to the specified site, but the delivery plan should be coordinated with the contractor’s receiving capacity, unloading equipment, storage conditions, and route to the electrical room. Confirm the requested ship-to location, access hours, staging area, and who will receive the equipment. Exact scope, availability, and timeline are confirmed for each order; do not schedule an event outage from an unapproved estimate.

Prepare a complete quote and handoff

For a useful quote, provide the latest one-line diagram, equipment schedules, system data, required standards and specifications, physical constraints, preferred component requirements, and a clear list of included and excluded scope. Note whether UL 891 switchboard assemblies are specified, along with any project requirements for metering, protective devices, control wiring, communications, or factory documentation. American-made components and custom-built configurations can be discussed against the project requirements, subject to confirmation for the order.

Before release, align the equipment submittal with the engineer, contractor, venue operations team, and purchasing manager. Confirm approved drawings, connection points, field responsibilities, delivery sequence, and the documents required for installation and commissioning. Gather the event calendar, outage constraints, and current electrical documents now, then send them with the equipment schedule and requested scope for a project-specific quotation.

Planning reference

Project specifications

Specifications are confirmed for each order
ScopeRequested by quote
VoltageBased on project requirements
CurrentSpecified to order
ListingDependent on the applicable assembly. UL 891 applies to applicable low-voltage switchboard assemblies, not medium- or high-voltage equipment.
Request a Quote