New electrical distribution equipment, built around your projectServing Georgia
Row of gray electrical control cabinets with switches and indicator lights.

Locations

Office Buildings Switchgear for Dunwoody, Georgia

Office projects in Dunwoody may need new switchgear for a tenant fit-out, a building expansion or replacement of aging distribution equipment. Each path brings different limits on service capacity, shutdown windows, electrical-room access and connection to existing systems. We build new switchgear to the project’s confirmed requirements, with configuration and delivery planning coordinated around the site.

Made in USAUL 891 switchboard assemblies — low voltage onlyAccelerated lead times — confirm availability
Project-specific

Define the application and requirements.

Built in the USA

Discuss equipment and assembly options.

Schedule-aware

Confirm lead times for your order.

Start with the building’s distribution plan

Map the incoming service, main distribution equipment, feeders and major loads before settling on an assembly. For an office, the load picture can include tenant panels, elevators, HVAC equipment, pumps, lighting, server rooms and shared amenities. Ask the electrical engineer to identify existing and planned loads, expected demand, spare capacity and any future tenant or floor changes that the distribution plan must accommodate.

Confirm the system voltage, phase, wire configuration, available fault-current information and grounding arrangement from project documents and utility coordination. These details affect bus and overcurrent-device requirements, compartment layout and equipment interfaces. Do not infer ratings from a neighboring building or an old panel schedule; have the engineer verify the applicable design basis for the specific Dunwoody site.

Fit the scope to an upgrade or new build

For a service upgrade in an occupied office, determine what existing equipment will remain, what must be replaced and where the transition points fall. Existing conduits, feeder routes, working clearances and electrical-room dimensions can constrain the new lineup. A proposed arrangement may need to account for temporary power, staged cutovers or limited shutdown periods, but the building team and electrical contractor must establish those plans with the engineer and utility as applicable.

For new construction or a major renovation, coordinate switchgear locations with the building layout early. Confirm access routes from receiving to the electrical room, doorway and corridor clearances, floor loading, equipment anchorage requirements and space for cable bends and future maintenance. These conditions can influence section sizes, orientation and shipping configuration. Final suitability depends on project engineering and review by the authority having jurisdiction; no general layout can establish approval for a particular building.

Specify the assembly and its interfaces

Prepare a one-line diagram and equipment schedule that show the intended main device, feeder devices, bus arrangement, metering needs and connections to downstream distribution. Identify required control power, protective functions, communications or monitoring interfaces, and any coordination or arc-flash study inputs the design team expects. Provide available drawings and revision dates so the proposed configuration can be checked against the current project documents rather than an outdated design.

UL 891 applies to switchboard assemblies. Where the project calls for a UL 891 switchboard, state that requirement and identify the sections and scope to which it applies. It is not a blanket listing for medium- or high-voltage switchgear. Confirm the required equipment type and applicable standards with the engineer; ratings, options, component selection and certification scope depend on the specified assembly and order.

Plan procurement around real constraints

Before requesting a quote, share the project location in Dunwoody, the project stage, requested quantity, target need date and whether the work is new construction, replacement or expansion. Include the latest one-line, equipment schedule, physical dimensions, utility or service information, fault-current data, connection details and known site access limits. Flag open engineering decisions instead of treating assumptions as confirmed requirements.

For procurement, ask which items are included, which project inputs remain unresolved, and what submittals are available for review. Confirm the proposed configuration, exclusions, options, drawing milestones and production schedule for the specific order. New equipment is built to the confirmed scope; component availability and timing are not assumed from a general product description. Resolve changes through documented drawing and scope review before release to manufacture.

Coordinate Georgia delivery and handoff

Delivery planning should connect the equipment configuration to the site’s receiving plan. Share unloading arrangements, delivery access, receiving hours, staging limits, required notices and any restrictions on truck approach or movement into the building. Dunwoody site conditions vary, so confirm these details with the property team and contractor rather than assuming a particular route, dock or storage area. We ship nationwide, including Georgia; delivery method and timing are confirmed for each order.

Before the equipment reaches the site, align the approved submittals with installation documents and identify the parties responsible for receiving inspection, rigging, installation, testing and energization. Qualified electrical professionals should perform work under the project’s approved plans and applicable authority review. To begin a Dunwoody office quote, assemble the current one-line, schedules, site dimensions, service and fault-current data, access constraints and target schedule, then identify any decisions the design team still needs to confirm.

Planning reference

Project specifications

Specifications are confirmed for each order
ScopeRequested by quote
VoltageBased on project requirements
CurrentSpecified to order
ListingDependent on the applicable assembly. UL 891 applies to applicable low-voltage switchboard assemblies, not medium- or high-voltage equipment.
Request a Quote