New electrical distribution equipment, built around your projectServing Georgia
Gray electrical switchgear below overhead conduit in an equipment room.

Locations

Data Centers Switchgear for Atlanta, Georgia

Atlanta data center projects must coordinate electrical redundancy with phased growth, construction sequencing, and the facility’s operating plan. We manufacture and supply new switchgear and UL 891 switchboard assemblies for project-specific configurations. Share the one-line diagram, load and redundancy criteria, expansion schedule, and site constraints so equipment scope and delivery can be evaluated against the project.

Made in USAUL 891 switchboard assemblies — low voltage onlyAccelerated lead times — confirm availability
Project-specific

Define the application and requirements.

Built in the USA

Discuss equipment and assembly options.

Schedule-aware

Confirm lead times for your order.

Translate redundancy into an equipment scope

“Redundant power” can mean different arrangements at different points in a data center. Identify the required utility, generator, UPS, and distribution paths, then show where each source enters and which loads each path serves. The one-line diagram should make normal, alternate, and maintenance configurations understandable, including any tie breakers or interlocks that affect operation.

For a quote, clarify which assemblies are included and where manufacturer scope ends. A switchboard serving a facility distribution point has a different role from equipment serving downstream rooms or critical loads. Confirm whether the project needs main, distribution, or tie sections; the number and arrangement of breakers; and the intended interfaces with upstream and downstream equipment. Final configuration depends on engineering review of the actual design.

Plan capacity for staged expansion

A campus may bring capacity online in phases while preserving room for later growth. Describe the initial installation and each planned expansion, including expected load changes, the construction sequence, and which areas must remain operational during additions. This helps determine whether the project calls for separate assemblies by phase, reserved spaces, or another arrangement selected by the engineer.

Do not assume that future capacity can be added simply by leaving physical space in a lineup. Bus and equipment ratings, available fault current, protective-device coordination, enclosure dimensions, cable access, and the electrical room layout all affect what can be accommodated. Provide known site data and identify assumptions that are still open. The project engineer can assess future provisions against the complete system and applicable authority requirements.

Resolve electrical and physical constraints

Share system voltage, phase and frequency, available fault-current information, grounding approach, required continuous-current ratings, and the protection or metering functions expected. Include the source and date of short-circuit data when available. If utility, generator, or UPS operating modes change the system conditions, explain those modes rather than relying on a single normal-operation value.

Atlanta-area sites can have tight equipment rooms, restricted access routes, active construction, and delivery windows that depend on other trades. Provide room plans, lineup limits, preferred cable-entry directions, conduit locations, access dimensions, and any known unloading or staging restrictions. These details help evaluate a buildable arrangement and Georgia delivery planning; they do not replace field verification or engineering approval.

Coordinate submittals and procurement

Procurement can begin with a clear distinction between confirmed requirements and pending decisions. Provide the project schedule, required submittal dates, approval sequence, desired shipment timing, and the date equipment must be available at the site. Short lead times may be a project priority, but availability and schedule are confirmed for each order after scope, components, and configuration are reviewed.

For UL 891 assemblies, identify the switchboard functions and sections that need to be included in the specified assembly. UL 891 applies to switchboards; it is not a blanket listing for medium- or high-voltage switchgear. State any separate equipment standards or specifications in the project documents so the requested scope can be reviewed accurately. Confirm the exact configuration and applicable documentation during order coordination.

Make the project handoff operationally useful

A complete handoff should give the facility team and installing contractor information that matches the approved equipment and site design. Coordinate equipment identification, source and load designations, control and indication requirements, breaker or metering details, and any project-specific interface information. Resolve discrepancies between the one-line diagram, schedules, specifications, and room drawings before release for manufacture.

The purchasing team should also confirm who reviews drawings, who approves deviations, and how revisions are communicated after approval. Installation, testing, commissioning, and energization must be performed by qualified personnel under the project’s approved procedures. Equipment scope alone does not establish that a complete installation meets design or code requirements; those determinations remain subject to engineering review and authority approval.

Prepare a useful quote request

For an Atlanta data center quote, send the current one-line diagram, equipment schedules, project specification, system data, room and access drawings, phased load plan, and target submittal and delivery dates. Note which requirements are fixed, which are alternatives, and which are still being developed. Include the project site location and delivery constraints so the proposed equipment and shipment plan can be evaluated for the actual site.

Before requesting pricing, list the required lineup functions, intended redundancy arrangement, expansion provisions, interfaces, and any preferred American-made components. Ask for scope clarification where drawings or specifications conflict. We manufacture and supply new equipment in the United States, with custom-built configurations and nationwide shipping; exact scope, availability, schedule, and Georgia delivery arrangements are confirmed for each order. Provide the project documents and open decisions together to support a practical review.

Planning reference

Project specifications

Specifications are confirmed for each order
ScopeRequested by quote
VoltageBased on project requirements
CurrentSpecified to order
ListingDependent on the applicable assembly. UL 891 applies to applicable low-voltage switchboard assemblies, not medium- or high-voltage equipment.
Request a Quote